Features
Handheld, rugged, lightweight
Multimode or single-mode applications
Wave ID (auto identification & switching)
Multiple-wavelength testing
270Hz, 330Hz, 1kHz, 2kHz Tone detection
Large LCD with backlight
Power measurements in dBm or µW;
insertion loss in dB
Reference power level storage
Automatic power-off function
Battery gauge
Long battery life with 2 x AA alkaline
N.I.S.T traceable
Applications
Premises (Ge), Telco (InGaAs), and
Broadband (+26 dBm) models
Passive Optical Networks (PON) testing
OPM4 Optical Power Meter
The Noyes OPM4 from AFL Telecommunications is a handheld optical power meter
designed for measuring optical power in Premises, Telco, or Broadband networks and for
performing insertion loss measurements on multimode or single-mode fiber optic links.
The OPM4 features automatic wavelength identification and switching (Wave ID)
when used with Noyes OLS series light sources, multiple test Tone detection for fiber
identification, and stores optical references for each calibrated wavelength. A large dual-
wavelength LCD display with backlight shows measured power [dBm or µW] or insertion
loss [dB], calibrated wavelengths [nm], tone signal [Hz], wavelength ID, and estimated
remaining battery life.
The OPM4 optical input port accepts a variety of Noyes thread-on style adapter caps
(ordered separately) to meet a wide range of testing requirements. The OPM4 offers a five-
minute auto-off feature and long battery life from common AA alkaline batteries.
The OPM4 is fully N.I.S.T. traceable.
Ordering Information
MODEL INCLUDES
All OPM4 models OPM4 optical power meter, 2 x AA batteries, protective rubber boot, user’s guide, and
carry case.
Specifications
OPTICAL OPM4-1D OPM4-2D OPM4-3D OPM4-4D
Calibrated
wavelengths
660, 780,
850 nm
850, 1300, 1310,
1490, 1550 nm
850, 1300, 1310,
1490, 1550, 1625 nm
850, 980, 1310, 1490,
1550, 1625 nm
Detector type Silicon (Si) Germanium (Ge) InGaAs Filtered InGaAs
Measurement range +6 to -70 dBm +6 to -60 dBm +10 to -75 dBm +26 to -50 dBm
Tone detect range +6 to -45 dBm +6 to -50 dBm
+6 to -45 for 850 nm
+10 to -50 dBm
+10 to -45 for 850 nm
+6 to -30 dBm
+6 to -25 for 850 nm
Wavelength ID
range
+6 to -50 dBm
+6 to -45 dBm for 850 nm
+6 to -30 dBm
+6 to -25 dBm for 850 nm
Accuracy
*
± 0.25 dB
Resolution 0.01 dB
Measurement units dB, dBm, µW
GENERAL
Power 2 x AA batteries
Battery life 300 hours
Operating tempera-
ture
-10 to 50°C, 90% RH (non-condensing)
Storage temperature -30 to 60°C, 90% RH (non-condensing)
Size (H x W x D) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in)
Weight 0.26 kg (0.58 lb)
* Accuracy measured at 25ºC and -10 dBm per N.I.S.T. standards.
All specifications at 25°C